M5310C On-Line TOC Analyser

M5310C-On-Line-water-200x270.png

Superior productivity

For both raw and finished water monitoring, the M5310 C promises you peace of mind when measuring organics in your plant or distribution systems. Engineered to support Disinfectants and disinfection Byproducts Rule (DBPR) compliance and with an analytical range of 4 parts-per-billion (ppb) to 50 parts-per-million (ppm), the M5310 C offers time-tested dependability with faster-than-ever analysis to help you reach the peak of productivity.

An unequalled level of efficiency and flexibility

  • Providing readings in only two minutes, the M5310 C analyzes TOC 50% faster than the 5310 C Series Analyzers.
  • Optional dual-Stream capability enables efficient sampling of two independent sample sources
  • Automated calibration, verification, and data analysis enable unattended operation. 
  • The Autoreagent feature automatically establishes optimal flow rates for each sample.
  • Saved methods are now available at the instrument. 

Easy to use and cost-effective

The M5310 C offers streamlined protocols, more informative error and alert messages, and a database structure for more useful ways to arrange, search and query data. Requiring only minimal preventative maintenance along with 12-month calibration stability, the M5310 C enables maximum uptime. Other feature enhancements include a large, color, and touch-screen displaying more intuitive menus.


Operating Specifications*

Range 4 ppb to 50 ppm
Precision < 1% RSD
Accuracy ± 2% or ± 0.5 ppb, whichever is greater
Display Readout 3 significant digits
Sample Type On-line continuous or discrete grab sample, timed on-line, TOC removal on-line, TOC removal grab
Calibration Typically stable for 12 months
Analysis Time 2 minutes
Sample Temperature** 5–95 °C (41–203 °F)
Ambient Temperature 4–40 °C (41–104 °F)
Sample Pressure Up to 100 psig
Required Sample Line Flow Rate >50 mL/min (for on-line mode)
Instrument Sample Flow Rate 0.5 mL/min
Analyzer Specifications
Inlets One stream, or two-stream inlet (option)
Outputs 4-20 mA outputs (3); alarm outputs (4); binary input (1);  USB device port (1), USB host ports (2); Ethernet
Display 7” WVGA 800x480 pixel, Color  LCD w/ touch-screen
Power 100 – 240 V~, 50 – 60 Hz, 100 VA
Dimensions H: 54.9 cm (21.6 in); W: 45 cm (17.7 in); D: 26.5 cm (10.4 in)
Weight 16.2 kg (35.6 lb)
Safety Certifications ETL, CE see Declaration of Conformity
Enclosure Rating IP-45
Environment
Maximum Relative Humidity 0 - 95%, non-condensing
Maximum Altitude 3,000 m (9,800 ft)
Pollution Degree 2
*Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors
**Sample temperature above 60 °C requires optional PVDF iOS