InnovOx Laboratory TOC Analyser

ox_vials_arm_270.jpgMeasures TOC Samples - All Day, Every Day

The new Sievers InnovOx Laboratory Total Organic Carbon (TOC) Analyzer represents a true breakthrough in high TOC measurement technology and reliability. The InnovOx (short for innovative oxidation) can consecutively handle thousands of common—as well as difficult samples such as brine and cellulose—with unprecedented system uptime. The InnovOx offers unparalleled oxidation robustness, a dynamic linear working range of 0.5 to 50,000 ppm, and calibration curve stability for industrial waste and environmental or process water samples.

Supercritical Water Oxidation (SCWO) Technique

GE Analytical Instruments' patent-pending Supercritical Water Oxidation (SCWO) technique enables the InnovOx to achieve its superior analytical performance and unsurpassed calibration stability. Using an oxidation process in a super critical state has shown superior TOC recoveries across a broad range of organic compounds and particulate impurities. This new process removes sample and precipitated impurities between each analytical run, eliminating sample matrices contamination and providing reliable, long-term system performance.

Versatile Measurement Modes

With the InnovOx, analysts can routinely test for Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), and Non-Purgeable Organic Carbon (NPOC). The InnovOx software provides versatile analysis options such as multiple runs on the same sample, auto calibration range selection, and integration with the Sievers 900 Autosampler.

Operating Specifications*

Analysis Modes TC, TIC, NPOC, TOC
Dynamic TOC Range 0.5 to 50,000 ppm
TOC LOD 0.05 ppm
TOC Accuracy ± 3% of reading at 50 ppm NPOC
TOC Precision RSD < 5% of reading at 50 ppm NPOC
TOC Linearity R2 > 0.995, measured as NPOC (see Operation & Maintenance Manual for calibration recommendation)
Analysis Time 2.2 to 7.3 min, depending on mode
TOC Calibration Stability Up to 6 months
Particle Diameters in Sample < 800 µm diameter
Ambient Operating Temperature Range 10-40 °C (50–104°F)
Maximum Relative Humidity Up to 95%, non-condensing
Sample Temperature Range 10-60 °C (50–140 °F)
Sample Inlet Pressue Ambient
Drain Gravity drain
Analyzer Specifications
Outputs Ethernet and 3 USB ports
Display Color, touch-sensitive LCD
Power 100–240 ± 10% VAC, 400 W, 50/60 Hz
Dimensions H: 52.05 cm (20.49 in); W: 32.26 cm (12.7 in); D: 58.42 cm (23.0 in)
Weight 22.4 kg (49.4 lb)
Safety Certifications CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 No. 61010-1.

* Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors