InnovOx On-Line TOC Analyser

ox_OL_blue_270.jpgMeasures TOC Samples - All Day, Every Day

GE Analytical Instruments designed the new Sievers InnovOx Total Organic Carbon (TOC) Analyzer to provide industry-leading sample handling robustness and instrument uptime for process, environmental, and wastewater TOC Analysis.The InnovOx On-Line joins the InnovOx Laboratory Analyzer in offering GE’s innovative Supercritical Water Oxidation technology for improved reliability, uptime, and robust handling of challenging sample matrices such as brine.

The new Sievers InnovOx On-Line Total Organic Carbon (TOC) Analyzer represents a true breakthrough in high TOC measurement technology and reliability. The InnovOx (short for innovative oxidation) can consecutively handle thousands of common—as well as difficult samples such as brine and cellulose—with unprecedented system uptime. The InnovOx offers unparalleled oxidation robustness, a dynamic linear working range of 0.5 to 50,000 ppm, 6-month calibration curve stability, user-configurable alarms and outputs, and an intuitive color touch-screen display. The InnovOx is extremely easy to set up, operate, and maintain, and offers a low cost of ownership.

Supercritical Water Oxidation (SCWO) Technique

GE Analytical Instruments' patent-pending Supercritical Water Oxidation (SCWO) technique enables the InnovOx to achieve its superior analytical performance and unsurpassed calibration stability. Using an oxidation process in a supercritical state has shown superior TOC recoveries across a broad range of organic compounds and particulate impurities. This new process removes sample and precipitated impurities between each analytical run, eliminating sample matrices contamination and providing reliable, long-term system performance.

Operating Specifications*

Analysis Modes TC, TIC, NPOC, TOC
Dynamic TOC Range 0.5 to 50,000 ppm
TOC LOD 0.05 ppm
TOC Accuracy ± ≤3% of reading at 50 ppm NPOC
TOC Precision RSD < 5% of reading at 50 ppm NPOC
TOC Linearity R2 > 0.995, measured as NPOC (see Operation & Maintenance Manual for calibration recommendation)
Analysis Time 2.6 to 8.3 min in online mode
TOC Calibration Stability Up to 6 months
Particle Diameters in Sample ≤ 200 µm diameter without filtration, > 200 µm with optional filter panel
Ambient Operating Temperature Range 10-40 °C (50–104°F)
Maximum Relative Humidity Up to 95%, non-condensing
Sample Temperature Range 10-60 °C (50–140 °F)
Sample Inlet Pressure Up to 125 psig
Drain Gravity drain
Analyzer Specifications  
Outputs Ethernet (Modbus and TCP/IP), Binary, 4-20 mA, and USB
Display Color, touch-sensitive LCD
Power 100–240 ± 10% VAC, 280 W, 50/60 Hz
Dimensions H: 92.7 cm (36.5 in); W: 64.6 cm (25.4 in); D: 38.7 cm (15.3 in)
Weight 36.3 kg (80 lb)
Safety Certifications CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 No. 61010-1.
IP Rating IP56 (optional)
Consumables***
Acid Reagent As needed
Oxidizer Reagent As needed
Reagent Grade Water As needed
Pumps 24 months
Sample Flow Path Tubing 12 months
Valve Seals (2) Up to 3 months, depending on sample matrix
Sample Pump Tubing (optional) 3 months
* Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.